What are the differences between Desire Fixtures (D22/D40/D60/D40XT/D40XTI/D60X/D60XTI)?
We do not manufacture fixtures using D40X or D60XT model numbers.
| Fixture / Feature | D22 Track/ Canopy ![]() |
D22
|
D40
|
D60
|
D40XT
|
D60X
|
D40XTI
|
D60XTI
|
|---|---|---|---|---|---|---|---|---|
| Primary Use | Fixed/semi-portable indoor | Portable Indoor | Portable Outdoor | Permanent Install Outdoor | ||||
| Power Input |
Permanent Cable to track adapter or canopy mount
|
Permanent Cable with regional connector
|
Neutrik PowerCon Connector (Blue)
|
Permanent Cable with Molded Molex Connector
|
Permanent Cable with Bare End
|
|||
| Power Thru | N/A | N/A |
Neutrik PowerCon Connector (White)
|
Permanent Cable with Molded Molex Connector
|
N/A | |||
| DMX Input | Track: via track pins Canopy: 8-pin Phoenix connector in canopy |
XLR Connector
|
Permanent Cable with XLR Connector
|
Permanent Cable with Bare End
|
||||
| DMX Thru |
Track: N/A Canopy: 8-pin Phoenix connector in canopy |
XLR Connector
|
Permanent Cable with XLR Connector
|
Included in Input Cable
|
||||
| LCD Screen / User Interface |
Yes, Full User Interface
|
No, RDM Configuration Only
|
||||||
| Accessory Mounting |
Accessory Slot / Color Frame Holder
|
Accessory Ring Only / No Color Frame Holder
|
||||||
| IP Rating |
IP20
|
IP66 for exterior, wet location use
|
||||||
| Fan? | No | Yes, menu-configurable -DMX -Slow -Fast -Auto |