Pharos Express Controller LED States
Issue
XPC Controllers can indicate a controller's state based on the front panel LEDs.
An XPC controller has (8) LEDs located on the front of the hardware on the left handside.

Standard LED States
- Power - Illuminates solid when the controller is powered from either POE or an external 9-48VDC power supply.
- Active - Once the boot up procedure has completed and is indicative of a fully functional unit.
- Ethernet - Indicates Pharos related network activity (not network link) while the remaining LEDs indicate communication on the various ports of the Express Control.
- Remote - Flashes when the unit has internet access, and will illuminate when the unit is connected to a Remote Site on Pharos Cloud or a Pharos Cloud Portal.
- I/O - Flashes with any activity on Express Control’s inputs or outputs.
- DALI - Illuminates with DALI power and flashes with DALI data activity.
- DMX - Indicates that valid DMX512 data is being output from the DMX ports.
- Output - Indicates that a valid project file has been loaded from the memory card and that playback and data output has started.
Error LED States
The controller LEDs can also indicate fault states, a controller in fault will be indicated in the following ways:
- Power LED lit
- Active LED off
- Ethernet, Remote, and I/Os LEDs double flashing followed by a 1 second pause.
- Dali LED lit solid = Memory card missing