My Foundry Mini Panel relays don't all turn on or off at the same time.

When I turn all of my relays on or off at the same time, there is a slight delay between each of the relays getting to their new state.

Foundry Mini Panels have a built in delay between relays. 

When multiple relays are turned on or off at the same time, there will be a slight delay between each relay getting to its new state. This built in delay is a safety measure and cannot be adjusted or disabled. The length of time depends on what firmware version your panel is running:

  • v1.0.0: 75ms
    • This means that for an 8 Zone Mini Panel, the total delay between relay 1 and relay 8 will be about .60 seconds.
  • v1.1.0 and up: 30ms​​​​​​
    • This means that for an 8 Zone Mini Panel, the total delay between relay 1 and relay 8 will be about .25 seconds.