Description/Explanation of Issue

I am trying to land wires on the panic input of the Unison Foundry Mini Panel but I am unsure where to land common.

Fix/Solution

There is a small triangle printed on the circuit board. That terminal would be where common is landed. In normal orientation this would be the bottom terminal.