Question
How do I put my CEM+ into test mode?
Answer
- Power off the rack from the main breaker. The CEM+ should be completely dark when this has been done
- Press the eject symbol to reveal the handle.
- Pull the handle to remove the CEM+ from the rack
- Use the chart below to locate the test switch and flip it over to test
- Reinstall the CEM+, making sure you feel it click into place.
- Power the rack back on
MPE
|

It is a red switch on the circuit board in the front right hand corner, labeled S2.
|
CEM Classic
|
 
It is the red switch on the circuit board just behind the Keypad of the front panel, labeled S1.
|
CEM+ (With Green Control Card)
|
 
It is a red switch on the circuit board halfway up the right side, labeled S2
|
CEM+ (With Blue Control Card)
|
 
It is a silver switch on the circuit board halfway up the right side, labeled S2.
|
CEM3 (without Heatsink)
|
 
It is a silver switch on the circuit board in the front right hand corner, labeled S2
|
CEM3 (with Heatsink)
|
 
It is a silver switch on the circuit board in the front right hand corner, labeled S3
|