Skip to main content
Electronic Theatre Controls Inc

CMd showing Arch Failure

Symptoms

CMd is showing Arch Failure

Explanation of Issue

The CMd has been configured as something that it isn't. The CMd does not have Arch hardware, so it will throw an error if configured incorrectly. Reconfiguring the CMd will fix this issue.

Fix/Solution

Be sure to note down the CMd's configuration prior to following these steps, as this will erase the configuration and return the CMd to a default state

Unison Processor Hidden Buttons.JPG

  1. Press and hold the "Initialization activate" hidden button, near the last N in Unison, until Menu shows up
  2. Press the Up arrow to get to the Menu Control Rack screen
  3. Change the Control from it's current setting to CMd
  4. Back out of the menu and select Yes when the CMd asks to update. The CMd will reset and load the correct configuration
  • Was this article helpful?