Convert Echo DRd to Paradigm DRd
Use the following components to convert from Echo DRd to Paradigm DRd Mk2
If the rack has an original Dimming Engine Mk1 you'll need:
- 1 ea. DRd Mk2 UPGRADE KIT 120V (7183A1751) --OR-- 1 ea. DRd Mk2 UPGRADE KIT 240V/277V
- These kits include a new dimming engine, left IO, right IO, CAT5 termination kit, and DMX termination kit
- 1 ea. P-ACP-E PARADIGM MK2 CNTRL PROC ENC (7180A1701)
- 1 ea. P-SPM-E PARADIGM STN PWR MOD MK2 (7182A1701)
- Desired quantity of Paradigm Heritage/Inspire/Responsive control stations
If the rack already has a Dimming Engine Mk2 or a Mk2 CPU2 you'll need:
- 1 ea. DRd PACP Mk2 TERM KIT LEFT/RIGHT I/Os (7180A1037)
- This kit includes the left IO, right IO, CAT5 termination kit, and DMX termination kit
- 1 ea. P-ACP-E PARADIGM MK2 CNTRL PROC ENC (7180A1701)
- 1 ea. P-SPM-E PARADIGM STN PWR MOD MK2 (7182A1701)
- Desired quantity of Paradigm Heritage/Inspire/Responsive control stations
Use the following components to convert from Echo DRd to Paradigm DRd Mk1
- 1 ea. PARADIGM DRd TERMINATION KIT (7180A1007)
- 1 ea. UNI DRD-PACP I/O LEFT ASSY (7183B5605)
- 1 ea. UNI DRD-PACP I/O RIGHT ASSY (7183B5606)
- 4 ea. SCR 6-32 X 1/4 Ph PH MS SEMS SS (HW213)
- 1 ea. PARADIGM ARCHITECTURAL CNTRL PROCESSOR 3 (7180A1029)
- 1 ea P-SPM-E PARADIGM STN PWR MOD MK2 (7182A1701) (not needed if there are no Lon-connected stations. It may still be needed to provide 24vdc Aux)
- Desired quantity of Paradigm Heritage/Inspire/Responsive control stations
Please note the existing Echo stations are not compatible with Paradigm therefore cannot be used after the DRd conversion.