EM64 Self Test Mode


 

The EM64's Self test mode allows you to run a number of diagnostic self tests.  

To enable the Self test mode. set Jumper 10 On, then set Jumpers 2, 3 and 4 as shown below to select the desired test. (If your EM64 is equipped with a thumb wheel, you may use it to select the desired test.) Then. reinstall the EM64 and press [Reset] to start the test. When you press [Reset]. all the LEDs flash, the EM64 resets to the new jumper settings, and the self test you have selected runs.

If your EM64 is equipped with the optional thumb wheel, you can use it to select a speed for the Chase, Fade all and Fade one tests without removing the module. Once the selected test is running, set the thumb wheel to the desired speed. Set the thumb wheel to zero to freeze the test. Thumb wheel settings from one to nine set the speed from the slowest rate to the fastest rate respectively. In the Level to al/ test, the thumb wheel allows you to set output levels of zero through nine.

Chase.png

Chase

The chase test runs through all the system's outputs from 1 through 64. This test confirms that all outputs are functioning. Set Jumpers 4 and 10 to On. Jumpers 1, 2 and 3 must be Off to run the test. You can adjust the speed of the test by changing the settings on your optional thumbwheel.

Fade All.png

Fade all 

This level test fades all outputs simultaneously from off to full and back to off one at a time. Set Jumpers 3 and 10 to On. Jumpers 1,2 and 4 must be Off to run the test. YOU can adjust the speed of the test by changing the settings on your optional thumbwheel. 

Fade One.png

Fade one

This level test fades all outputs simultaneously from off to full and back to off one at a time. Set Jumpers 3 and 10 to On. Jumpers 1,2 and 4 must be Off to run the test. YOU can adjust the speed of the test by changing the settings on your optional thumbwheel.

Level to all .png

Level to all

This test raises all outputs to a specified level. Set Jumpers 2, 4 and 10 to On. Jumpers 1 and 3 must be off to run the test. Use the optional thumbwheel to set the desired level between 0 and 9. If you don't have the thumb wheel installed. outputs rise to a default level of 50%.