There are multiple encoder options that can be used with ETC Rigging 3rd Party Controls.
Fixed Speed Motor Starter (FSMS):
- TTL Encoder (Differential Signal)
- 5-30 VDC Supply
- 5V Signal
- HTL Encoder (Differential Signal)
- 5-30 VDC Supply
- Requires HTL -> TTL Conversion Card
- Quadrature Encoder (Single Ended Signal)
- 10k Analog Pot
Variable Speed Motor Starter (VSMS):
- TTL Encoder (Differential Signal)
- 5-30 VDC Supply
- 5V Signal
- HTL (Differential Signal)
- 5-30 VDC Supply
- Requires HTL -> TTL Conversion Card
- 10k Analog Pot
- For use with SoftLift Fixed Speed Control Only, not reccommended.
Motor Control Interface (MCI):
- TTL Encoder (Differential Signal)
- 5-30 VDC Supply
- 5V Signal
- HTL (Differential Signal)
- 5-30 VDC Supply
- Requires HTL -> TTL Conversion Card
- 10k Analog Pot
ETC recommends using Belden 9728 or equivalent for encoder field wiring.
Encoder Type |
Signal Level |
Supply Voltage |
Signal Output Voltage |
TTL |
High |
4.75 - 30 VDC |
3V Min (5V Max) |
|
Low |
4.75 - 30 VDC |
0.5V Max |
HTL* |
High |
4.75 - 9 VDC |
3V Min |
|
High |
9 - 30 VDC |
Supply Voltage - 3V (Min) |
|
Low |
4.75 - 30 VDC |
0.5V Max |
*Requires an HTL -> TTL Conversion Card