ETC Rigging 3rd Party Control enclosures are designed to connect directly to a 4-wire or 6-wire (Wheatstone bridge) strain gauge load cell.
If a 4-wire load cell is used the Sense+ & Excitation+ and Sense- & Excitation- are connected together as shown in the wiring example below .
MCI Load Cell Wiring Example


Note: 4-20 mA load cells are not directly compatible with ETC Rigging 3rd Party controls. Please contact ETC Technical Services or your Project Manager for additional information.