Symptoms/Issue

After configuring ArtNet input, ArtNet input does not work.

Description/Explanation of Issue

Some reasons that ArtNet input could not work

  • HogNet and FixtureNet IP addresses are in the same range
  • The external ArtNet source is in the wrong IP address range

Fix/Solution

  1. Check that the HogNet and FixtureNet IP addresses are not in the same range
    If the FixtureNet IP is 10.0.0.1, then make sure that HogNet IP address does not start with 10
  2. Make sure that the ArtNet source and the FixtureNet IP addresses are in the same range
    If the FixtureNet IP is 10.0.0.1, then make sure the ArtNet source's IP address begins with 10 and is configured correctly based on the netmask.