How to Set Up Dimmer Doubling Multiplexing In Sensor Classic Rack
Question
How do I enable and set up dimmer doubling Multiplex for circuits in my Sensor Classic rack?
Answer
The steps depend on what software version the CEM is running.
Steps
For software v3.X
- From the Home screen, tap [Setup]
- Tap [1] for Dimmer and tap [Enter]
- Tap the [Up] or [Down] arrow button or enter the number for the dimmer you want to adjust and tap [Enter]
- Tap [>] until you reach the Mode page
- Tap the [Up] or [Down] arrow buttons until you get to DD and tap [Enter]
- Repeat for any other dimmers you want to adjust.
For software v2.X
- Enable MUX on the system level
- From the Home screen, tap [Setup]
- Tap [3] for System and tap [Enter]
- Tap [>] until you reach the MUX page
- Tap the [Up] or [Down] arrow button to select Enabled and tap [Enter]
- Enable MUX on the DMX input port
- From the Home screen, tap [Setup]
- Tap [2] for Rack and tap [Enter]
- Tap [>] until you reach the Port A MUX or Port B MUX page
- For this, you will need to know which port will be using DD
- Tap the [Up] or [Down] arrow button to select Yes and tap [Enter]
- Enable MUX on the dimmer(s)
- From the Home screen, tap [Setup]
- Tap [1] for Dimmer and tap [Enter]
- Tap the [Up] or [Down] arrow button or enter the number for the dimmer you want to adjust and tap [Enter]
- Tap [>] until you reach the Mode page
- Tap the [Up] or [Down] arrow buttons until you get to Multiplex and tap [Enter]